How Sync Works Between Deltek Vantagepoint and Newforma Konekt
3 minutes
11 hours ago
The integration between Deltek Vantagepoint and Newforma Konekt follows a one-way model, with changes in Deltek Vantagepoint reflected in real-time in Newforma Konekt but not the other way around.
Project and user updates in Deltek Vantagepoint follow specific sync rules based on how the integration is configured.
Project Sync Rules
These sync rules apply specifically to projects:
- Mapped fields sync automatically from Deltek Vantagepoint to Newforma Konekt: For example, if the Project number field is mapped in the connector, any changes made to project numbers in Deltek Vantagepoint will be reflected in Newforma Konekt for synced projects.
- Mapped fields can only be edited in Deltek Vantagepoint: Once a field is mapped in the connector, it becomes read-only in Newforma Konekt. For example, if the Project Number field is mapped in the connector, you can no longer edit it in Newforma Konekt for synced projects. To update the project number of these projects, make the change in Deltek Vantagepoint, and it will then be reflected in Newforma Konekt.
- Unmapped fields can be edited in Newforma Konekt: If a field is not mapped in the Deltek Vantagepoint configuration, it can be edited in Newforma Konekt, as updates from Deltek Vantagepoint will not be synced for that field.
- Deleted records in Deltek Vantagepoint no longer sync: For example, if a synced project is deleted in Deltek Vantagepoint, it will still exist in Newforma Konekt but will stop receiving updates from Deltek Vantagepoint. All project fields will then become editable in Newforma Konekt.
- Unchecking the Create in NK <name of hub> custom field in Deltek Vantagepoint stops sync: For example, if you uncheck the Create in NK <name of hub> custom field for a synced project, that project in Newforma Konekt will no longer receive updates from Deltek Vantagepoint. All project fields will then become editable in Newforma Konekt.
Users Sync Rules
These sync rules specifically apply to users:
- User information is synced only once: After the initial sync, updates to a user’s personal information in Deltek Vantagepoint are no longer synced to Newforma Konekt. Any updates to the user’s personal information must be made directly in Newforma Konekt.
- Users are added to synced projects automatically: If a Deltek Vantagepoint user is added to a project that is synced to Newforma Konekt—and both the user and the project have the Create in NK <name of hub> field checked—the user will also be added to that project in Newforma Konekt. Similarly, if the user is removed from the synced project in Deltek Vantagepoint, they will also be removed from the project in Newforma Konekt.
- Users are disabled in Newforma Konekt if removed, terminated or switched to inactive in Deltek Vantagepoint: A user will be disabled in Newforma Konekt if they’re created from Deltek Vantagepoint and then either:
- Removed from Deltek Vantagepoint or
- Terminated in Deltek Vantagepoint or
- Has their status switched to inactive in Deltek Vantagepoint
- Unchecking the Create in NK <name of hub> custom field in Deltek Vantagepoint stops sync: For example, if you uncheck the Create in NK <name of hub> custom field for a synced employee or contact, that user in Newforma Konekt will no longer receive updates from Deltek Vantagepoint.